- Metering Systems
-
Gas Valves
Gas Valves
-
Water Valves and Taps
Water Valves and Taps
-
Metal boxes
- Motorised Valves
- Industrial Ball Valves
Top Test
For use of the valve limited to the user concerned
The Toptest series, gas valves with pressure outlet, is designed following the entry into force of the Uni CIG 7129 standard of 2008 which requires the use of the gas valve limited exclusively to the user concerned. For this purpose, if necessary, taps with keys, niches and lockers with keys for exclusive use, other similar devices are considered suitable.
The range of gas valves belonging to the Toptest series includes different combinations: straight, angled and with meter connection. All models are equipped with a pressure point for testing the system in addition to the closure with a default lock.
The pressure outlet must be positioned downstream of the shutter with respect to the flow direction of the system.
The Toptest valves supplied by Enolgas, when equipped with a cap with gasket, are mounted and tested for its tightness, therefore we decline all responsibility for improper use by third parties.
Toptest ball valves are for full bore combustible gas with pressure point and UNI EN 10226 threaded ends.
They are suitable for all types of gas (city, methane and liquid gas) as well as hot and cold water and compressed air distribution systems.
The Toptest series gas ball valves are approved according to EN 331.
Material specification
Approved to EN 331
COMPONENT |
MATERIAL |
DESCRIPTION |
||
---|---|---|---|---|
1 | BODY | CW 617 N UNI EN 12165 | FORGED, NICKEL-PLATED | |
2 | END ADAPTER | CW 617 N UNI EN 12165 | FORGED, NICKEL-PLATED | |
3 | BALL | CW 614 N UNI EN 12164 | MACHINED, CHROME-PLATED | |
4 | BALL GASKETS | P.T.F.E. | PURE | |
5 | STEM | CW 614 N UNI EN 12164 | MACHINED | |
6 | THRUST WASHER | P.T.F.E. | PURE | |
7 | O-RINGS | ELASTOMER | SUITABLE FOR USE WITH GAS EN549 | |
8 | LEVER HANDLE | ZINC-PLATED STEEL | PVC INSULATED | |
LEVER OR T-HANDLE | AL UNI5076 | PAINTED | ||
9 | SELF-LOCKING NUT | 8G STEEL | ZINC-PLATED | |
10 | PLUG | CW 614 N UNI EN 12164 | FORGED |
Characteristics
INTERNATIONAL APPROVALS | The gas ball valves of the TOP TEST series are certified EN 331. They gained official approvals in various countries for use with gas. |
THREADS | Ends threaded UNI EN 10226. |
USES |
Fuel gas:
The TOP TEST ball valves are also suitable for hot and cold water, compressed air, oils and hydrocarbons in general. |
WORKING PRESSURE | For fuel gas 5 MOP. For other uses from PN 40 (1/2”) to PN 30 (2”). See diagram pressure/temperature. The tightness tests are in accordance with the UNI EN 331 standard. |
TEMPERATURE LIMITS | For fuel gas from -20°C to +60°C. For other uses from -20°C to + 100°C with tap. See pressure/temperature diagram. |
Pressure/temperature diagram
(tested performed with water)
Head loss diagram
(tested performed with water)
Head loss diagram
(tested with air)
IMPORTANT NOTE
The pressure gauge has to be positioned downstream the ball as to the installation flow direction.
The valves furnished by Enolgas which have a tap with gasket are assembled and tested on the basis of its tightness, so any responsibility is declined for improper use by third parties.
Download
Top Test 1.68 MB